Auto restart when overload
06
occurs
Auto restart when over
07
temperature occurs
09
Output frequency
10
Operation Logic
10
Operation Logic
Maximum utility charging
11
current
Setting voltage point back
to utility source when
12
selecting "SBU" (SBU
priority) or "SUB" (Solar
first) in program 01
Restart disable (default)
Restart disable (default)
50Hz (default)
Automatically (default)
Online mode
ECO Mode
2A
20A
40A
60A
80A (only for OG-Plus 5.48RM)
Available options for 24V:
Default setting: 23.0V
Available options for 48V:
15
Restart enable
Restart enable
60Hz
If selected and utility is
available, inverter will work
in line mode. Once utility
frequency
is
unstable,
inverter will work in bypass
mode if bypass function is
not forbidden in program
23.
If selected, inverter will
work in line mode when
utility is available.
If selected and bypass is not
forbidden in program 23,
inverter will work in ECO
mode when utility is
available.
10A
30A (default)
50A
70A (only for OG-Plus
5.48RM)
The setting range is from
22.0V to 28.5V and
increment of each click is
1.0V.

Advertisement