Kodak OG-Plus3.24RM Installation & User Manual page 16

Solar off grid inverter
Table of Contents

Advertisement

Maximum charging current:
To configure total charging
current for solar and utility
02
chargers.
(Max. charging current =
utility charging current +
solar charging current)
05
Battery type
60A (default)
AGM (default)
User-Defined
Pylontech battery
WECO battery (only for
OG-Plus 5.48RM model)
Soltaro battery (only for
OG-Plus 5.48RM model)
LIb-protocol compatible battery
3
rd
party Lithium battery
14
The setting range is from
10A to 120A for OG-Plus
3.24RM model and 10A to
140A for OG-Plus 3.48RM
model. The setting range is
from 10A to 160A for
OG-Plus 5.48RM model.
Increment of each click is
10A.
Flooded
If "User-Defined" is
selected, battery charge
voltage and low DC cut-off
voltage can be set up in
program 26, 27 and 29.
If selected, programs of 02,
26, 27 and 29 will be
automatically set up. No
need for further setting.
If selected, programs of 02,
12, 26, 27 and 29 will be
auto-configured per battery
supplier recommended. No
need for further
adjustment. Setting
parameters in Programs 12
and 13 parameters change
to SOC (State of charge) of
battery.
If selected, programs of 02,
26, 27 and 29 will be
automatically set up. No
need for further setting.
Select " LIb" if using Lithium
battery compatible to Lib
protocol. If selected,
programs of 02, 26, 27 and
29 will be automatically set
up. No need for further
setting.
If selected, programs of 02,
26, 27 and 29 will be
automatically set up. No
need for further setting.
Please contact the battery
supplier for installation
procedure.

Advertisement