ATTENTION! If you hold down button 3 for more than 10 seconds, the display will show a
countdown 333...222...111... You must release the button before this time expires in order
not to reset all settings of this mode to the standard factory settings. This will be discussed
in the next paragraph.
Similarly, when button 11 is pressed, the digital display on the right shows the graphic
name of the current function of the wire feeder, and immediately after releasing it for 2
seconds, the current value of that function is shown. The buttons 7 can be used to change it
up or down.
If the menu is locked, as in the case of the function menu on the source, just hold down this
button for more than 3.5 seconds.

6.2 SWITCHING TO THE REQUIRED WELDING MODE

Press button 4 to select the desired welding mode. The modes are switched in a circle. This
can be seen on the display 2.

6.3 RESETTING ALL FUNCTIONS OF THE CURRENT WELDING MODE

There may be situations where the settings in the unit are somewhat confusing to the user.
In order to reset the settings to the factory default values, it is necessary to use the same
button 3, which is used to enter the function menu. To reset the settings, it is simply
enough to hold the button 3 for more than 10 seconds (do not pay attention to the locks
displayed). The display will start counting down 333...222...111 and when "000" is reached,
all settings of the current welding mode will be reset to the factory settings. The
parameters for each welding mode are reset separately. This is done for convenience not to
reset the individual settings in the other two modes.
Similarly, you can reset the settings on the wire feeder with the button 11.

6.4 CHANGING THE PROGRAM NUMBER IN THE CURRENT WELDING MODE

The user can store up to 16 different presets in each of the MMA, TIG and MIG/MAG
welding modes. The number of the current setting (programme) is displayed in the upper
right-hand corner of the source's LCD display on the front panel. When the unit is first
switched on, the programme is always at number 1 for each welding mode. All changes to
the unit's settings in that welding mode and the current programme number are saved.
To switch to a new programme number and restart the setting from the basic parameters,
simply press button 3. If the function selection menu is locked, the LCD will show the
current programme number, which can be changed up or down using buttons 1.
If the function selection menu is not locked, for example: the user has just before that
changed the additional function parameters described in paragraph 6.1, it is necessary to
lock the function selection menu by holding down button 3 for more than 3.5 seconds, in
the same way as when unlocking. The indicator will show the closing locks.