5Maintenance and Inspection

5.3.2 Installing/removing the cover

<3> No.2 arm cover B
(Back of No.2 arm cover)
Note) The cover
on the top
face of the
No.1 arm is
not removing.
<4> ADD cover
(lower side of back of base)
Fig.5-3 : Installing/removing the cover
CAUTION
Maintenance and inspection procedures
5-77
Replace the packing when the cover was mounted/removed. Please contact
dealer. If the cover is used without replacing the packing, chemicals or oil mist
may enter inside the arm and cause a malfunction.
<1>
No.2 arm cover U
<2>
No.2 arm cover D
<6> Duct piping box
(upper side of back of base)
(A ventilation duct is attached)
<5> Battery cover
* The model is an example.