Huawei SUN2000-8K-LC0 Series User Manual page 103

Hide thumbs Also See for SUN2000-8K-LC0 Series:
Table of Contents

Advertisement

SUN2000-(8K, 10K)-LC0 Series
User Manual
Alarm ID
Alarm
Name
2039
AC
Overcurr
ent
2040
DC
Compon
ent
Overhigh
2051
Abnorma
l
Residual
Current
Issue 01 (2023-09-15)
Alarm
Possible Causes
Severity
Major
Cause ID = 1
The grid experiences a
dramatic voltage drop or is
short-circuited. As a result,
the transient AC current of
the device exceeds the
upper threshold and
triggers protection.
Major
Cause ID = 1
The DC component in the
AC current exceeds the
upper threshold.
Major
Cause ID = 1
The insulation impedance
of the input side to PE
decreases when the device
is operating.
Copyright © Huawei Digital Power Technologies Co., Ltd.
8 System Maintenance
Troubleshooting
1. The device detects its external
working conditions in real
time. After the fault is
rectified, the device
automatically recovers.
2. If the alarm occurs frequently
and affects the energy yield
of the power plant, check
whether the output is short-
circuited. If the fault persists,
contact your dealer or
technical support.
1. The device detects its external
working conditions in real
time. After the fault is
rectified, the device
automatically recovers.
2. If the alarm occurs frequently,
contact your dealer or
technical support.
1. If the alarm occurs
occasionally, the external
circuit may be abnormal
temporarily. The SUN2000
automatically recovers after
the fault is rectified.
2. If the alarm occurs frequently
or persists, check whether the
impedance between the PV
string and the ground is too
low.
96