GUIDE TO TROUBLESHOOTING

CASE 1: IGNITION FAILURE

Check that the freeze prevention system is operated.
Check to see if the fuel is
mixed in water or if the
mixing ratio is incorrect.
if not
Check if the engine is
flooded.
if not
Check the sparkplug

CASE 2: LACK OF POWER. POOR ACCELERATION. MINIMUM SPEED

Check to see if the fuel
is mixed in water or if the
mixing ratio is correct.
if not
Check for obstruction
in the air filter or fuel
filter.
if not
Check if the carburation is
correct.
Replace with proper fuel.
if yes
Remove and dry the spark
plug. Pull the starter again
without choke.
if yes
Change the spark plug
if not
Replace with proper fuel.
if yes
Clean
if yes
Adjust the position of the HL
screws as said in the point:
adjusting the carburetor
if not
EN I 77