Dynacord V Series Installation Manual page 46

Table of Contents

Advertisement

46
en | Technical data
Connectivity
    Type
    Maximum input level (LEVEL 0 dB)
    Input impedance, active balanced
Mains input
Loudspeaker output
Control port
    Type
    REMOTE ON
    READY/FAULT
General
Signal processing
Power requirements
Power consumption
    Consumption at 1/8 rated output power
    Idle mode (ecoRAIL with no input signal)
    Standby mode (APD active)
Power supply topology
Protections
Front status LEDs
Environmental
Climatic conditions
Cooling concept
2024.01 | V03 | F.01U.402.248
Installation manual
6‑pin Euroblock, 3.81 mm, male,
parallel 1x RJ45
+18 dBu
20 kΩ
IEC C14
4-pin Euroblock, 5.08 mm, female
5‑pin Euroblock, 3.81 mm, male
Remote On / Standby contact
(overrides power button on front
panel)
Galvanic isolated relay, max.
30 V
/ 500 mA
DC
DC
Input routing, HPF 24 dB/Oct.
selectable 100/150 Hz, LPF 24 dB/
Oct. selectable 150 Hz, Flat, Peak
limiter
100 V to 240 V, 50 Hz to 60 Hz AC
115 W
<12 W
<1 W
Switching power supply with power
factor correction
Audio limiters, high temperature,
DC, HF, short circuit, back‑EMF,
peak current limiters, inrush current
limiters, mains over/under voltage
protection
Signal, limit, fault LEDs per channel;
power LED
Convection cooling in tabletop
application and rack application
with spacing between units. Forced
V Series
Dynacord