Dynacord L300 Owner's Manual

Dynacord L300 Owner's Manual

Linear precision power amplifiers
Table of Contents

Advertisement

Available languages

Available languages

BEDIENUNGSANLEITUNG
OWNER'S MANUAL
L300 L500 L1000 L1600 L2400
Linear PRECISION POWER AMPLIFIERS

Advertisement

Table of Contents
loading

Summary of Contents for Dynacord L300

  • Page 1 BEDIENUNGSANLEITUNG OWNER‘S MANUAL L300 L500 L1000 L1600 L2400 Linear PRECISION POWER AMPLIFIERS...
  • Page 2: Table Of Contents

    INHALT WICHTIGE SICHERHEITSHINWEISE ....... WICHTIGE SERVICEHINWEISE ....... BESCHREIBUNG ....... FRONTSEITE ....... RÜCKSEITE ....... INPUT A / INPUT B ....... PARALLEL ....... ENDSTUFENAUSGÄNGE ....... BRIDGED MODE ....... GROUND-LIFT SCHALTER ....... TECHNISCHE DATEN ....... BLOCK DIAGRAM ....... ABMESSUNGEN ....... CONTENTS IMPORTANT SAFETY INSTRUCTIONS .......
  • Page 3: Wichtige Sicherheitshinweise

    WICHTIGE SICHERHEITSHINWEISE Das Blitzsymbol innerhalb eines gleichseitigen Drei- ecks soll den Anwender auf nicht isolierte Leitungen und Kontakte im Geräteinneren hinweisen, an denen hohe Spannungen anliegen, die im Fall einer Berührung zu lebensgefährlichen Stromschlägen führen können. Das Ausrufezeichen innerhalb eines gleichseitigen Dreiecks soll den Anwender auf wichtige Bedienungs- sowie Servicehinweise in der zum Gerät gehör- enden Literatur aufmerksam machen.
  • Page 4: Beschreibung

    Wir möchten Ihnen zu allererst danken und Sie beglückwünschen, daß Sie sich für die Endstufen der LINEAR PRECISION SERIE entschieden haben. Die DYNACORD - Endstufen der LINEAR PRECISION SERIE erfüllen auch die extremen Anforderungen harten Tour-Betriebs. Sie sind gegen Überhitzung, Überlast, Kurzschluß sowie Hochfrequenz und Gleichspannung am Ausgang geschützt.
  • Page 5: Frontseite

    FRONTSEITE 1. Pegel-Regler Geeichte Rastpotis zur Veränderung der Gesamtverstärkung der Endstufe. Zur Vermeidung von Verzerrungen in vorgeschalteten Mischpulten sollten diese Regler normalerweise zwischen 0dB und - 6dB eingestellt werden. Die geeichte Beschriftung zeigt unmittelbar die zusätzliche Reglerdämpfung mit der die intern festgelegte Verstärkung verändert wird. 2.
  • Page 6: Rückseite

    RÜCKSEITE RÜCKSEITE Endstufeneingangsbuchsen Parallel zu den XLR Eingangsbuchsen ist jeweils eine Buchse zum „Weiterschleifen“ zu weiteren Endstufen vorgesehen. Die Eingänge der Endstufe sind elektronisch symmetrisch ausgeführt und nach der IEC Norm 268 beschaltet. Zur Beseitigung von Brummstörungen in größeren Anlagensystemen können Übertrager nachgerüstet werden. Bitte wenden Sie sich bei derartigen Problemen an Ihren Fachhändler.
  • Page 7: Bridged Mode

    RÜCKSEITE Endstufenausgangsbuchsen Für die Endstufenkanäle A (Links) und B (Rechts) sind jeweils SPEAKON Ausgangsbuchsen vorhanden. Die Bridged-out Buchse für den Brückenbetrieb ist mit einem Kunststoffdeckel geschlossen, um Anschlußfehler zu vermeiden. LIMITER Der eingebaute Limiter zur Vermeidung von Übersteuerungen ist in seiner Zeitkonstante umschaltbar. Normalerweise sollte die Stellung „SLOW“...
  • Page 8: Technische Daten

    TECHNISCHE DATEN Models L 300 L 500 L 1000 L 1600 L 2400 (20Hz - 20kHz / THD = 0,1%) Output Power into 8 Ohms 2 x 100 W 2 x 175 W 2 x 350 W 2 x 500 W 2 x 750 W nto 4 Ohms 2 x 150 W...
  • Page 9 OWNER‘S MANUAL L300 L500 L1000 L1600 L2400 Linear PRECISION POWER AMPLIFIERS...
  • Page 10: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS The lightning fl ash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of suffi cient magnitude to constitute a risk of electric shock to persons.
  • Page 11: Description

    First of all we should like to thank and congratulate you for choosing the power amplifi ers of the LINEAR PRECISION SERIES. DYNACORD power amplifi ers of the LINEAR PRECISION SERIES meet the most stringent requirements of tough touring applications. They are protected against high-temperature, overload, shorted outputs, radio frequency interference and DC faults.
  • Page 12: Front Panel

    FRONT PANEL 1. Level Control Calibrated detented potentiometers to alter the total gain of the power amplifi er. In order to avoid distortions in mixing consoles upstream, these controls should normally be positioned between 0 dB and -6 dB. The calibrated markings show the additional attenuation directly. 2.
  • Page 13: Rear Panel

    REAR PANEL REAR SIDE Power amplifi er input connectors XLR connectors (male) are provided for “Looping” the signal to other power amplifi ers. These are wired parallel to the XLR input connectors in each channel. The inputs of the power amplifi er are electronically balanced and wired according to IEC 268.
  • Page 14: Amplifier Output Connectors

    REAR PANEL POWER AMPLIFIER OUTPUT CONNECTORS SPEAKON output connectors are provided for the power amplifi er channels A (left) and B (right). The Bridged Out Connector for bridged operation is sealed with a plastic cover to prevent connection errors. LIMITER The time constant of the built-in limiter to avoid overdriving is adjustable.
  • Page 15: Specifications

    SPECIFICATIONS Models L 300 L 500 L 1000 L 1600 L 2400 (20Hz - 20kHz / THD = 0,1%) Output Power into 8 Ohms 2 x 100 W 2 x 175 W 2 x 350 W 2 x 500 W 2 x 750 W nto 4 Ohms 2 x 150 W...
  • Page 16 BLOCKDIGRAMM L300 L500 L100...
  • Page 17 BLOCKDIGRAMM L1600 L2400...
  • Page 18 ABMESSUNGEN / DIMENSIONS Abmessungen / Dimensions (in mm)
  • Page 20 Telex Communications Inc., 12000 Portland Ave. South, Burnsville, MN 55337, Phone: +1 952-884-4051, FAX: +1 952-884-0043 Germany EVI AUDIO GmbH, Hirschberger Ring 45, D 94315, Straubing, Germany Phone: 49 9421-706 0, FAX: 49 9421-706 265 Subject to change without prior notice. Printed in Germany 10/02/2006 / 349 519 www.dynacord.de...

This manual is also suitable for:

L500L1600L1000L2400

Table of Contents