V Series
5.2.4
Ready/Fault relay
The Ready/Fault relay is a potential free relay toggle for READY or FAULT indication. This
allows the amplifier to notify an external device or indicator that the amplifier status is
either "RDY" (all is ok) or "FLT" (fault) and may not be functioning correctly. The next table
explains the relay setting for the different operation and error modes.
READY (RDY) / FAULT (FLT)
RDY
FLT
FLT
FLT
*) RDY/FLT: Indicates the closed contact.
Figure A shows the FLT (fault) condition, figure B shows the RDY (all is ok) condition.
Refer to
–
Dynacord
Indicators, controls and settings, page 25
Description
Amp active, all channels on
APD is activated or device is not on
One or more channels in Protect state
Internal error, e.g. fan blocked