SMC Networks EX180-SAW1-X237 Operating Manual

Si unit for anywireaslink

Advertisement

Quick Links

No.EX※※-OMV1029
PRODUCT NAME
SI unit for AnyWireASLINK
MODEL / Series / Product Number
EX180-SAW1-X237

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX180-SAW1-X237 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks EX180-SAW1-X237

  • Page 1 No.EX※※-OMV1029 PRODUCT NAME SI unit for AnyWireASLINK MODEL / Series / Product Number EX180-SAW1-X237...
  • Page 2: Table Of Contents

    Contents Safety Instructions How to Order Summary of Product Parts Installation and Cabling General Instructions on installation Connecting cables LED Display and Settings Troubleshooting Specifications Dimensions No.EX※※-OMV1029...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 4 Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
  • Page 6 ■NOTE ○Follow the instructions given below when designing, selecting and handling the product. The instructions on design and selection (installation, wiring, environment, adjustment, operation, described below must also be followed. maintenance, etc.) Product specifications When conformity to UL is necessary the SI unit must be used with a UL1310 Class2 power supply. The SI unit is a UL approved product only if they have a mark on the body.
  • Page 7 Environment Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result. Do not use in an area where surges are generated. If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, motor, etc.) close to the fieldbus system, this may cause deterioration or breakage of the internal circuit of the fieldbus system.
  • Page 8: How To Order

    How to Order Summary of Product Parts Communication connector (1 pc.) Accessories Element Description Fieldbus interface connector The connector ( ) used to connect to the AnyWireASLINK bus line. (BUS) FG terminal Functional Earth. Display LED diagnostic display. Set the address using a dedicated address writer. Address setting port Refer to page for details of the address setting.
  • Page 9: Installation And Cabling

    Installation and Cabling ■General Instructions on Installation ○Applicable valve series The EX180 series SI unit can be mounted on the following valve manifolds. Manifolds SJ2000, SJ3000, S0700 series : Refer to the catalogues and operation manuals for details on the solenoid valves and manifolds. How to mount the manifold 1.
  • Page 10: Led Display And Settings

    LED Indication and Settings ○LED Indication LED description Display Description No transmission LINK Flashing Normal operation Broken wire to the DP/DN terminals, or no power supply Reduced I/O voltage Flashing Reduced transmission signal level Normal operation Alternate Flashing LINK When the master unit detects that the ID (address) LINK is duplicated or not set.
  • Page 11 ○Address setting The SI unit address number corresponds to the controller I/O memory map. This addressnumber is assigned to the AnyWireASLINK transmission frame (0 to 254), and the SI unit will occupy 32 points, starting from the last assigned number. The addressnumber can be set using a single unit (1 point).
  • Page 12 ○Output number assignment Combinations of output data and valve manifold : The output number refers to the solenoid position on the manifold and starts at zero. : Standard wiring on the manifold is for double-solenoid valves and output number starts A side and B side in that order as shown in the Figure a.
  • Page 13: Troubleshooting

    Troubleshooting <LINK LED is not flashing> Check items Actions Check the SI unit connection. Remove the SI unit and connect it again. Check whether the master unit LINK LED is flashing, then take the following actions. (1) If the master unit LINK LED is flashing and the SI unit LINK LED is ON, there is a possibility that the master unit has been damaged.
  • Page 14: Specifications

    Specifications Item Specifications Applicable system AnyWireASLINK (4-wire (insulation)) Power supply for SI unit: 24 VDC (Supplied from the AnyWireASLINK transmission line) Power supply voltage range Power supply for the solenoid valves: 24 VDC +10%/-5% (Voltage drop warning is generated at approximately 16 V) Power supply for SI unit: 0.1 A or less Current consumption...
  • Page 15: Dimensions

    ■Dimensions Unit: mm -14- No.EX※※-OMV1029...
  • Page 16 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2018 SMC Corporation All Rights Reserved. No.EX※※-OMV1029...