Leica Piper 100 User Manual page 81

Hide thumbs Also See for Piper 100:
Table of Contents

Advertisement

Setting up the
Trivet Assembly
and Mounting
Bracket
81
5.
Observe the Target. Adjust the pipe so that the laser beam is centred
on the cross-hairs.
The Leica Geosystems AG Trivet Assembly (746158) includes the
mounting bracket that is attached to the bottom of the laser.
1.
Remove the four feet from the Piper, then
attach the mounting plate by re-installing the
feet.
2.
Attach the Piper with the mounting bracket to
the Trivet Assembly and secure by tightening
the 5/8 "-11 knob and stud assembly to the
bracket.
3.
Set the line. Place the Trivet Assembly in a
way that the Piper is aligned with the pipe to
be laid. Turn the knobs on the Trivet plate
until the bubble is centred in the Piper's
cross-axis level vial. Tighten the brass lock
nuts to lock the feet in place.
4.
Set the grade. Enter the required grade to the Piper (see
Grade
for further information). The Piper can self-level over its entire
grade range. It is not necessary to tip the laser to achieve grade.
Basic Operation
Entering

Advertisement

Table of Contents
loading

This manual is also suitable for:

Piper 200Piper 100g/3Piper 100g/2Piper 200g

Table of Contents