Leica Piper 100 User Manual page 63

Hide thumbs Also See for Piper 100:
Table of Contents

Advertisement

Environmental
specifications for
Piper 100/200
63
Temperature
Type
Instrument
Battery
Charger and
AC/DC power sup-
ply
Type
Instrument
Battery
Charger and
AC/DC power sup-
ply
Technical Data
Operating temperature
[°C]/[°F]
-20 to +50/-4 to +122
-20 to +55/-4 to +131
±0 to +40/+32 to +104
Protection against water, dust and sand
IPx8 (IEC 60529)
Dust tight
Protected against continuous immersion in water
IP54 (IEC 60592)
Dust protected
Protection against splashing water from any direction
IPX0 (IEC 60592)
Only operate in dry environments, for example in build-
ings and vehicles.
Storage temperature
[°C]/[°F]
-40 to +70/-40 to +158
-20 to +30/-4 to +68
-20 to +30/-4 to +68

Advertisement

Table of Contents
loading

This manual is also suitable for:

Piper 200Piper 100g/3Piper 100g/2Piper 200g

Table of Contents