6.10

COMMISSIONING

To commission the device, perform the following operations.
6.10.1 Preliminary checks
Check that the device has been
connected to the ground cable.
OBLIGATION
Check that the line voltage cor-
responds to that indicated on the
device plate.
ATTENTION
Check that the device is free from
tools or utensils of various kinds.
VISUAL IN-
If present, remove them.
SPECTION
6.10.2 General cleaning
Do not pour or spray water on
the product.
Do not clean the surfaces with
PROHIBITION
easily flammable substances
(for example: alcohol or paint
thinners).
Clean only the external surface
using a soft and dry cloth.
MANUAL
CLEANING
6.10.3 Commissioning of the plant
• Fill the tank completely via the inlet faucet and check that
there are no water leaks from gaskets and connections.
• Do not exceed the max. permissible pressure indicated in
the "general technical data" section.
• Check the water circuit safety devices.
• Plug the unit into the power outlet.
• When the plug is inserted, the unit is OFF.
To turn on the unit, refer to paragraph "2.5.1 Power on" on
page 123
In case of a sudden power outage, when restored the equip-
ment will restart from the operating mode prior to the interrup-
tion.
90 LT - 120 LT
cod. 3540000400 - Rev. 03 - 09/2023
6.10.4 Query, editing operating parameters
This
equipment
has
ing
and
modifying
For details, refer to chapter "2. USE OF THE WATER HEAT-
ER" on page 121.
NB!: Use of the password is reserved for qual-
ified personnel; any consequences due to
incorrect parameter settings will be the sole
responsibility of the customer. Therefore,
any interventions requested by the custom-
er from an authorised technical assistance
centre FERROLI S.p.A. during the standard
warranty period, for product problems due to
incorrect settings of password-protected pa-
rameters, will not be covered by the standard
warranty.
7.

REPLACEMENTS

Incorrect repairs may put the
user in serious danger. If your
device needs any repair, con-
ATTENTION
tact the technical assis-
tance service.
Any intervention on the de-
vice, including disposal, must
be performed by qualified per-
sonnel with a suitable Refrig-
eration Technician's Licence
aimed at the knowledge and
EXPERT
R290
TECHNI-
management of systems con-
CIAN
taining HC type gases such as
R290 (Propane).
Before undertaking any main-
tenance operation make sure
the equipment is not and can-
ATTENTION
not accidentally be electrically
powered.
Therefore, turn off the de-
vice and remove the plug
from the socket.
distinct
menus
for
the
operating
parameters.