Ferroli EGEA TECH 90 LT User, Installation, And Maintenance Manual page 128

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 112
NOTA:
* : for the correct reading of this parameter, the va-
lue resulting from the 3 screens must be divided by 10.
Ex. 02859 / 10 = 285,9
** : for the correct reading of this parameter, the value re-
sulting from the 3 screens must be multiplied by 10.
Ex: 02859 x 10 = 28590
2.8.6 rSt menu - RESET
Para-
Description
meter
n01 Weekly programming reset
n02 Energy monitoring counter reset
Level: U=user menu - I=installer menu
To perform the reset:
set the parameter = 1
power off the unit
power on the unit.
2.8.7 Inf MENU - MACHINE STATUS INFORMATION
To view the general information, access the Inf menu by pres-
sing the "SET"
key and scrolling with the "+" and "-" keys,
the values "I01" to "I13" will appear.
Para-
Description
meter
Currently active operating
0:6 (0=OFF, 1=STANDBY, 2=ECO, 3=AUTO,
I01
mode
4=BOOSTER, 5=ELECTRIC, 6=FAN)
I02
real water set point*
°C
I03
External air temperature
°C
I04
Lower water temperature
°C
I05
Higher water temperature
°C
I06
Evaporator inlet temperature °C
Evaporator outlet tempe-
I07
°C
rature
Compressor delivery tem-
I08
°C
perature
I09
Coil temperature
°C
PT1000 solar probe tempera-
I10
°C
ture (unusable)
I11
-
Reserved
Calculated evaporation
I12
°C
temperature
Calculated condensing
I13
°C
temperature
Electronic expansion valve
I14
Step
opening
I15
Fan rpm number
rpm / 10
-
I16
WiFi module firmware
I17
Motherboard firmware
-
-
I18
Display firmware
-
I19
Parameter version
Level: U=user menu - I=installer menu
* : the displayed value also takes into account any offsets linked to the
activation of the auxiliary functions (photovoltaic, smartgrid, solar thermal,
anti-legionella).
Press the "ON/OFF"
key to exit the menu.
EN
128
Note Level min
max
Livello
U / I
-
0
0
1
U / I
-
0
0
1
Note
Level
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
cod. 3540000400 - Rev. 03 - 09/2023
EGEA TECH
2.8.8 HI menu - ELECTRIC HEATER SETTING
Value
Description
Enabling heater in ECO mode when
H01
protection alarm
(0=disabled, 1=enabled)
Electric heater ignition upper probe
H02
hysteresis (only for Electric and Booster
modes)
Operating time in AUTO mode for
H03
temperature rise control for switching
on the electric heater
Minimum increase in water temperature
H04
so as not to turn on the heating element
in AUTO mode
Level: U=user menu - I=installer menu
Parameters:
H01: from this parameter it is possible to enable or disable the
switching on of the heater when the unit is working in ECO
mode and the compressor cannot switch on due to an inter-
vention of one of its protections (for example intervention of the
HP pressure switch or air temperature at outside the operating
limits):
H02: Difference between the set point and the heater switch-
on temperature
H03 – H04: These parameters are used when the unit is wor-
king in AUTO mode and you want the heater to be turned on
when the water temperature does not rise by a minimum in-
crease (H04) after a given pump operating time of heat (H03).
NOTE: once turned on, the heater will turn off only when the
water temperature reaches the set point
2.8.9 Phv menu - EVU functionality - Photovoltaic functio-
nality
If parameter G01=1 is set (smartgrid enabled), the
EVU and photovoltaic functions are not available. To
enable them, set parameter G01=0 (smartgrid not ena-
bled).
2.8.9.1 EVU functionality (see also "6.8.1 Remote connec-
tions")
This function is indispensable if a subsidized electricity tariff is
subscribed for heat pumps. The aim is to facilitate operation
when the cost of electricity is low, but still having to comply with
the rules of the energy supplier who will be able to decide when
to interrupt the supply.
To meet this requirement, the water heater electronics are fit-
ted with a digital input which, when opened, allows the unit to
be switched off and thus reduce the load on the electricity grid.
NOTE: When enabled and active, this feature takes priority
over the PV feature.
To set the parameters, access the phv menu, by pressing the
90 LT - 120 LT
Unit of
default min
max
Level
measure
-
I
0
0
1
I
°C
7
0
20
I
min
30
0
120
I
°C
4
0
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Egea tech 120 lt

Table of Contents