Ferroli Talent Installation And Use Instructions Manual
Ferroli Talent Installation And Use Instructions Manual

Ferroli Talent Installation And Use Instructions Manual

Wall mounted fan flue gas multi-point water heater

Advertisement

Quick Links

Phone numbers:
Installer ____________________________
Service Engineer _____________________
°
Serial N
____________________________
3541027/4 • 10/2002
Supplied By www.heating spares.co Tel. 0161 620 6677
TALENT
Wall Mounted
Fan Flue
Gas Multi-Point Water Heater
These Instructions must be left with the appliance User.
Wall mounted fanned
flue Water Heater
INSTALLATION AND
USE INSTRUCTIONS
Please read these Instructions
thoroughly before using
the appliance

Advertisement

Table of Contents
loading

Summary of Contents for Ferroli Talent

  • Page 1 TALENT Wall Mounted Fan Flue Gas Multi-Point Water Heater Wall mounted fanned flue Water Heater Phone numbers: Installer ____________________________ INSTALLATION AND USE INSTRUCTIONS Service Engineer _____________________ ° Serial N ____________________________ Please read these Instructions thoroughly before using the appliance These Instructions must be left with the appliance User.
  • Page 2 S.p.A. INDEX 1 - General description and information 2 - Technical specifications 3 - Installation details 4 - Installation 5 - Water heater connections 6 - Commissioning, operation and shutdown 7 - Adjustments 8 - Converting to L.P.G. 9 - Maintenance requirement 10 - Handing over to user Supplied By www.heating spares.co Tel.
  • Page 3 S.p.A. 1. GENERAL DESCRIPTION AND INFORMATION 1.1 Information 1. Installation must be carried out by a competent person, and in accordance with the relevant requirements of the current issues of: A. Gas Safety (Installation & Use) Regulations. 1994 B. Building Regulations. C.
  • Page 4 S.p.A. - A high limit thermostat - A steel room-sealed compartment treated against corrosion, enclosing components. - An air differential pressure switch which, to ensure safe operation, allows burner ignition only when the fan functions normally. - A newly-designed gas ignition valve assembly, comprising a fullly modulating gas valve and a flame control device.
  • Page 5: Technical Specification

    S.p.A. TECHNICAL SPECIFICA TION 2.01. Technical Data Model Natural gas (G20) Propane LPG (G31) Nominal Heat Input (Gross C.V.) 29.7 11.5 29.0 11.3 Nominal Heat Input (Net C.V.) 26.8 10.4 26.8 10.4 Nominal Heat Output 24.4 24.4 Natural Gas LPG. (G20) (G31) Pilot Injector...
  • Page 6 S.p.A. 2.02. Dimensions and Measurements °C °C 1. Domestic hot water outlet 2. Domestic cold water inlet 3. Gas supply a. Main electrical switch b. LED - Power on (green) LEDs - Temperature level (yellow) c. Water temperature control knob (40°C - 55°C) d.
  • Page 7 S.p.A. 2.03. Flow Diagram Fig. 2 5 Room-sealed compartment 29 Internal flue exit 7 Gas inlet 30 Surplus air collector 8 Domestic hot water outlet 31 Air pressure control damper 9 Cold water inlet 40 Expansion vessel 3 bar 16 Fan 42 Temperature sensor 19 Combustion chamber 43 Air pressure switch...
  • Page 8: Installation Details

    3.2 Location of the water heater The installation of the TALENT must be on a suitable non-combustible load bearing wall which will provide an adequate fixing for the boiler mounting bolts. The location should be in an area where the water pipes will not be subjected to frost conditions.
  • Page 9 S.p.A. Terminal Position Fig. 3 Minimum Clearance mm min. 25 mm 25 mm 600** °C °C Fig. 4 NOTES ** Access to the front of the boiler must be available for maintenance (min. 600 mm). Supplied By www.heating spares.co Tel. 0161 620 6677...
  • Page 10 S.p.A. 3.5 Flue system The water heater allows the flue outlet to be taken from the rear of the water heater or from either side. A standard flue length of 0.75 metres is provided. Alternative lengths of two or three metres can be supplied.
  • Page 11: Installation

    S.p.A. 4. INSTALLATION 4.1 Unpacking The appliance is delivered in 2 cartons. 4.1.1 The large carton contains the boiler, and the Installation/Servicing and Users Instructions. 4.1.2 The second carton contains the wall fixing bolts (x2), flue assembly, water heater bend and gas cock.
  • Page 12 S.p.A. 4.3 Preparing the flue assembly The water heater is supplied with 0.75 m of concentric flue which can be run from either side or to the back of the appliance. If a longer flue is required 2 m and 3 m lengths are avaiable. An example of using the concentric flue.
  • Page 13 S.p.A. 5. Water heater connections Gas, Water and Electrical °C °C Front View Side View 1. Hot water outlet 1/2" 2. Cold water inlet 1/2" 3. Gas Supply 3/4" 5.1 Gas supply 1. Further guidance: BS 6891, BS 6798, Gas Safety (Installation and Use) Regulations 1994. 2.
  • Page 14: Natural Gas

    Ferroli disclaims any liability for damages to persons, animals or property caused by lack of earthing of the heater or by an electrical system which does not comply with current regulations.
  • Page 15 - In the event ignition of the pilot flame has failed, check the line and neutral connections for correct polarity. 6.3 Operation Talent is a water heater designed for prompt production of hot water. During drawing of domestic water, the flowmeter sends a signal to the electronic device which, in response to the preset temperature and the desired flow, adjusts the gas valve.
  • Page 16 7. ADJUSTMENTS The TALENT water heater is factory set and no adjustments ar e normally required, however the following adjustments can be made if problems are found. 7.1 Adjusting the pressure and flow rate at the main bur n er This appliance, being of the modulating-flame type, comes with two fixed pressure settings - for minimum and maximum, as shown in the table - for each type of operating gas.
  • Page 17 S.p.A. - Regulate the minimum pressure by turning nut “e”, anticlockwise to reduce it and clockwise to increase it. - Turn the burner off three or four times by closing and opening the gas cock, checking every time that the pressure level corresponds to the new setting and that the burner ignites normally.
  • Page 18 8. CONVER TING FROM ONE OPERA TING GAS TO ANOTHER The following conversion and adjustment procedures are to be performed solely by qualified personnel. Ferroli disclaims any liability for any material and/or personal damages caused by tampering with the appliance by unauthorized persons.
  • Page 19 S.p.A. 9. MAINTENANCE REQUIREMENT For continued reliable use it is a good practice to have a qualified person check the appliance at least once a year. Prior to performing any work related to cleaning, maintenance and opening or removing panels of the water heater, shut the power down (by turning the main electric switch off), and turn off the gas cock.
  • Page 20: Phone Numbers

    Phone numbers: Installer Service Engineer BECAUSE OF OUR CONSTANT ENDEAVOUR FOR IMPROVEMENT DETAILS MAY VARY SLIGHTLY FROM THOSE QUOTED IN THESE INSTRUCTIONS. ALL SPECIFICATIONS SUBJECT TO CHANGE Lichfield Road, Branston Industrial Estate, Burton Upon Trent, Staffordshire DE14 3HD Tel. 08707 282 885 - Fax 08707 282 886 Supplied By www.heating spares.co Tel.

Table of Contents