Electrical Connections - Ferroli EGEA TECH 90 LT User, Installation, And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 112
fig. 58- Example of condensate drain connection with a trap
6.8

ELECTRICAL CONNECTIONS

The device is equipped with a power cable with Schuko plug
to be connected to the power grid via a suitable socket (fig. 59
and fig. 60).
fig. 59 - Schuko socket
The device must be installed in
compliance with the regulations
on electrical systems in force in
ATTENTION
the country of installation.
Connect the device to an efficient
grounding system.
OBLIGATION
Do not use extension cords or
adapters.
PROHIBITION
For connection to mains and
safety devices, comply with the
IEC 60364-4-41 standard.
ATTENTION
EN
154
60mm
fig. 60 - Unit plug
cod. 3540000400 - Rev. 03 - 09/2023
EGEA TECH
Fixed devices are not equipped
with means of disconnection
from the mains with a separation
ATTENTION
of the contacts on all poles ca-
pable of guaranteeing complete
disconnection in the overvolt-
age category III, the instruc-
tions indicate that the means of
disconnection must be integrat-
ed in the fixed wiring in compli-
ance with the wiring regulations.
The device must be protected by
an adequate differential switch.
The type of differential switch
ATTENTION
should be selected by assess-
ing the type of electrical devices
used by the system as a whole.
DO NOT TAMPER WITH THE
POWER CORD.
If the power supply cable is dam-
ATTENTION
aged, it must be replaced by the
manufacturer or the technical as-
sistance service or in any case
by a person with similar qualifi-
cations, in order to prevent any
risk.
90 LT - 120 LT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Egea tech 120 lt

Table of Contents