Graco CGM Instructions And Parts page 14

Communications gateway module
Table of Contents

Advertisement

Pointer
Designa-
Description
tion
Red Material Inline
88
Heater Zone, temperature
Blue Material Inline
90
Heater Zone, temperature
Red Material Hose Heat
92
Zone, temperature
Blue Material Hose Heat,
94
temperature
Red Material Chiller
96
Zone, temperature
Blue Material Chiller
98
Zone, temperature
Heater Zones Enabled Bit
102
Masks
103
Heater Zones On/ Off Bit
Masks
104
Current Tank Level
120
Status
121
Tank Filling Control/
Status, Red Tank
122
123
Tank Filling Control/
Status, Blue Tank
124
Ratio, Setpoint
130
Comments, Data Element descriptions
Current Zone Actual Temperature, in 0.1 C
Current Zone Actual Temperature, in 0.1 C
Current Zone Actual Temperature, in 0.1 C
Current Zone Actual Temperature, in 0.1 C
Current Zone Actual Temperature, in 0.1 C
Current Zone Actual Temperature, in 0.1 C
Bit 0 = Red Tank Zone Enabled (1) or Disabled (0).
Bit 1 = Blue Tank Zone Enabled or Disabled.
Bit 2 = Red Inline Heater Enabled or Disabled.
Bit 3 = Blue Inline Heater Enabled or Disabled.
Bit 4 = Red Hose Heater Enabled or Disabled.
Bit 5 – Blue Hose Heater Enabled or Disabled.
Bit 6 = Red Chiller Enabled or Disabled.
Bit 7 = Blue Chiller Enabled or Disabled.
Bit 0 = Red Tank Zone Turned ON (1)/ Off (0).
Bit 1 = Blue Tank Zone Turned ON/ Off.
Bit 2 = Red Inline Heater Turned ON/ Off.
Bit 3 = Blue Inline Heater Turned ON/ Off.
Bit 4 = Red Hose Heater Turned ON/ Off.
Bit 5 – Blue Hose Heater Turned ON/ Off.
Bit 6 = Red Chiller Turned ON/ Off.
Bit 7 = Blue Chiller Turned ON/ Off.
Least Significant Byte – Red Tank Level
nd
2
Significant Byte – Blue Tank Level
Level indications/ Byte:
1 = Material is below Low Level sensor.
2 = Material between Low and High Level (2
3 = Tank Full (at 2
7 = Material at or above top sensor ("Report xxx High
Level in bit 2" feature ON).
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
In 0.001:1 units of measure. So for instance, a value of
23680 = 23.680:1. Ratio may be inverted based on the
setting of the "Ratio:" control selection on the System #3
setup screen.
Ratios are either volumetric or weight depending upon the
"Flow Units" Selection on the ADM Advanced #2 setup
screen.
CGM Interface Manual, HFR/ NVH (Small Map with Data Exchange) Applications, March 25, 2022, Page 14 of 23
o
units.
o
units.
o
units.
o
units.
o
units.
o
units.
nd
sensor, or above).
Read/
Write
Read
Read
Read
Read
Read
Read
Read
Write
Read
Read
nd
) sensors.
Write
Read
Write
Read
Read