Graco CGM Instructions And Parts page 16

Communications gateway module
Table of Contents

Advertisement

Pointer
Designa-
Description
tion
Set or Read Register
183
"Configurable Data
Command 2" Assignment
(Output instance 9, O104
184
– O119)
Set or Read Register
185
"Configurable Data
Command 3" Assignment
(Output instance 10,
186
O120 – O135)
Set or Read Register
187
"Configurable Data
Command 4" Assignment
(Output instance 11,
O136 – O151)
188
Mixed Material in Current
200
or Last Dispense
Blue Material in Current
202
or Last Dispense
Red Material in Current or
204
Last Dispense
Mixed Material
206
Resettable Counter
Blue Material Resettable
208
Counter
Red Material Resettable
210
Counter
Pump Resettable Counter
212
Reset All Resettable
213
Material Counters
Mixed Material Total
220
Counter
Blue Material Total
222
Counter
Red Material Total
224
Counter
Total Pump Cycle
226
Counter
231
Dynamic Mixer Speed
Set Point.
232
Dynamic Mixer Actual
234
Speed
Comments, Data Element descriptions
Register assignments must be an Odd number, and
correspond to any Write Assignment in this Table. Once set
(Write), the HFR/ NVH will remember the assignment, even
after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Register assignments must be an Odd number, and
correspond to any Write Assignment in this Table. Once set
(Write), the HFR/ NVH will remember the assignment, even
after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Register assignments must be an Odd number, and
correspond to any Write Assignment in this Table. Once set
(Write), the HFR/ NVH will remember the assignment, even
after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Sum of Blue and Red Materials Dispensed (In 0.01 CC or
0.01 Gram units)
(In 0.01 CC or 0.01 Gram units)
(In 0.01 CC or 0.01 Gram units)
Sum of Blue and Red Resettable Counters (In 0.01 CC or
0.01 Gram units)
(In 0.01 CC or 0.01 Gram units)
(In 0.01 CC or 0.01 Gram units)
(in pump cycles)
Will set all the resettable counters to 0. System must be idle
(Pumps NOT moving) for this command to execute.
Sum of Blue and Red material dispensed from HFR or NVH
(In 1 CC or 1 Gram units)
Sum of Blue material dispensed from HFR or NVH (In 1 CC
or 1 Gram units)
Sum of Red material dispensed from HFR or NVH (In 1 CC
or 1 Gram units)
Total number of pump cycles for the NVH/ HFR system.
In RPM. Only valid if using Dynamic Mixer (Voltex) option.
In RPM. Only valid if using Dynamic Mixer (Voltex) option.
CGM Interface Manual, HFR/ NVH (Small Map with Data Exchange) Applications, March 25, 2022, Page 16 of 23
Read/
Write
Write
Read
Write
Read
Write
Read
Read
Read
Read
Read
Read
Read
Read
Write
Read
Read
Read
Read
Write
Read
Read

Advertisement

Table of Contents
loading