5.1

Location and Space Requirements

The SAVE VTC 200 – 1 should preferably be installed in a
separate room (e.g. storeroom, laundry room or similar.).
When choosing the location it should be kept in mind that
the unit requires maintenance regularly and that the in-
spection door should be easily accessible. Leave free
space for opening the door and for taking out the main
components (figure 5).
5.2

Wall preparation for mounting bracket

The unit should be installed in such a way that there is no vibration noise
coming from the wall on which the unit is installed.
5.3

Outdoor Air Intake Location Recommendation

Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.4

Access to Power supply

The SAVE VTC 200 – 1 is supplied with approximately 1 – 1,5 m cable and plug for 230V, single phase earthed
connection.
Make sure a power outlet is reachable by the plug.
6

Installation

Important
The device may only be installed by qualified, instructed and trained personnel. The persons must know the
relevant safety directives in order to recognise and to avoid risks.
398085 | v01
Installation |
1000
Fig. 5
7