Prerequisites For Installation; Location And Space Requirements; Outdoor Air Intake Location Recommendation; Access To Power Supply - SystemAir SAVE VSC 100 Installation Instructions Manual

Hide thumbs Also See for SAVE VSC 100:
Table of Contents

Advertisement

5

Prerequisites for Installation

SAVE VSC 100 is designed for ceiling installation. Left and right connections are possible.
5.1

Location and Space Requirements

The SAVE VSC 100 should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
Note:
SAVE VSC 100 must be installed in a heated
area.
When choosing the location it should be kept in mind that
the unit requires maintenance regularly and that the in-
spection door should be easily accessible. Leave free
space for opening the door and for taking out the main
components.
5.2

Outdoor Air Intake Location Recommendation

Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.3

Access to Power supply

The SAVE VSC 100 is supplied with approximately 1 – 1,5 m cable and plug for 230V, single phase earthed connection.
Make sure a power outlet is reachable by the plug.
6

Installation

Important
• The device may only be installed by qualified, instructed and trained personnel. The persons must know
the relevant safety directives in order to recognise and to avoid risks.
333585 | v1.1
Prerequisites for Installation |