Status Messages Temperature Controller; Intended Use; Unintended Use - Scholl 2009 Instructions For Use Manual

Plate warmer
Table of Contents

Advertisement

GBA A 0201 1 E
5.1.1 S
TATUS MESSAGES TEMPERATURE CONTROLLER
Message
Cause
"AUS" or "OFF"
Standby modus, no regulation
F1L
Sensor error,
short-circuit at sensor
F1H
Sensor error,
open-circuit at sensor
Buzzer
Temperature alarm or sensor error
EP, display flashes
Data loss at parameter memory
(Contacts K1 and K2 are switched off)
5.2
I
NTENDED USE
Practice:
 Switch on the temperature controller (standby key).
 The display of the temperature controller shows the actual temperature (actual value).
 Press the SET key to display the set temperature (set value).
 Set the temperature controller to the desired temperature (SET key, UP key, DOWN key).
 The LED 1 lights up when the temperature controller heats
 After the heating time, the device is ready for operation and can be equipped with the plates.
 For switching off after use:
 Switch off the temperature controller (standby key).
The set temperature (set value) will be stored even after switching off the temperature controller. The last
set temperature (set value) is active after switching on the temperature controller.
Do not touch the device surfaces. The surfaces of the device may grow hot. Please
let the device cool off entirely before cleaning it. Do not cover the device.
Danger of burns and fire!
5.3
U
NINTENDED USE
Please observe strictly:
 Plate warmer are
not
for defrosting/warming up of deep-frozen/cooled food.
BA
Last revised 01-2018
Error elimination
Switch on with standby key
Check sensor
Check sensor
The buzzer function can be switched off
with the DOWN-key
If error cannot be eliminated by switching
on/off, the controller must be repaired
Page 13 of 23
Januar 18, 2018
Rev. 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

20112012A 0201A 0302A 0402