Direct-Run Wire Length Chart
This type of wire configuration allows for long distances between the transformer and the
appliances (see illustration below). Use the charts below to determine the correct wire gauge
and length.
24 Volt Lead
Wire
min
14 GA
max
242'
min
12 GA
max
369'
min
10 GA
max
566'
* Not available on some transformers.
Wiring Examples:
Daisy-Chain Installations:
When using 3 appliances on one branch, 14 ga wire, and 150' of wire, use the 28V Lead.
When using 4 appliances on one branch, 10 ga wire, and 100' of wire, use the 24V Lead.
Direct Run Installations:
When using an appliance on a 200' run, 14 ga wire, use the 24V Lead.
When using 6 appliances, each on a 200' run, 14 ga wire, use the 24V Lead.
How to Determine Wire Gauge: When purchasing your wire, it should include a wire gauge (the larger the
number, the smaller the diameter wire). The wire will also be printed with a gauge number (e.g., AWG#14 = 14
gauge, 10AWG = 10 gauge, etc.). Do not use wires of dissimilar gauges (do not use 14 gauge & 10 gauge wire on
the same transformer).
© Travis Industries, Inc.
Installation
26 Volt Lead*
Wire
0'
14 GA
0'
12 GA
0'
10 GA
10/26/23 - 1579
(qualified installers only)
min
79'
max
384'
min
120'
max
584'
min
184'
max
897'
Outdoor Complete Linear Fire Pits
28 Volt Lead*
Wire
min
234'
14 GA
max
499'
min
356'
12 GA
max
760'
min
548'
10 GA
max
1168'