Pneumatic Connection - Burkert 2063 Series Operating Instructions Manual

Piston-controlled diaphragm valve
Hide thumbs Also See for 2063 Series:
Table of Contents

Advertisement

→ Pressurise pilot air port 2 with compressed air (value as indi-
cated on the type label).
→ Actuate the diaphragm valve twice to position the diaphragm
correctly.
→ With applying pressure, tighten the body screws in three
stages (approx. 1/3, approx. 2/3, 3/3 of the full tightening
torque, according to "Tab. 10"), in each case tightening them
cross-wise. The diaphragm should be positioned and pressed
evenly all around the actuator and body.
DN (diaphragm
Tightening torques for diaphragms [Nm]
size)
EPDM/FKM PTFE/ advanced PTFE/ lami-
8
2.5
15
3.5
20
4
25
5
32
8
40
8
50
12
Tab. 10:
Diaphragm tightening torques for mounting the drive
→ A tolerance of +10% of the respective tightening torque
applies to all values.
26
7.6
Risk of injury from unsuitable connection hoses.
▶ Use only hoses which are authorized for the indicated pressure
▶ Observe the data sheet specifications from the hose
For control function I: Risk of pilot pressure failure.
The valve stays in an undefined position in the event of a pilot
pressure failure.
▶ To ensure a controlled restart, first pressurize the device with
nated PTFE
2.5
7.6.1
4
Control function A and B
4.5
→ Connect the control medium to pilot air port 1.
6
Control function I
10
→ Connect control medium to pilot air port 1 and 2.
10
15
English
Type 2063, 2064, 2065
Technical data

Pneumatic connection

WARNING!
and temperature range.
manufacturers.
pilot pressure, then switch on the medium.
Connecting the control medium
Pressure on pilot air port 1 opens the valve.
Pressure on pilot air port 2 closes the valve.
If used in an aggressive environment, we recommend
conveying all free pneumatic connections into a neutral
atmosphere with the aid of a pneumatic hose.

Advertisement

Table of Contents
loading

This manual is also suitable for:

2064 series2065 series

Table of Contents