35. Adjusting the timing of the upper knife
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power off and ascertaining that the motor is at rest.
Standard adjustment
❶
❷
❸
Screw No. 1
(B)
64
–
–
Direction of rotation
(A)
<Cross-sectional view
of cam C>
The screw No. 1 faces
perpendicularly upward
when the knife is in its
upper dead point.