25. Adjusting the floating of the disk of the thread tension controller
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power off and ascertaining that the motor is at rest.
Standard adjustment
Clearance: 0.9 mm or more
❸
❶
❷
❺
❻
❹
Close contact
Clearance: 0.9 mm or more
When the clearance is too large
When the clearance is too small
❽
❼
44
–
–