Route Configuration - evertz 7700 Manual

Unidirectional umd protocol translator
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

7700 MultiFrame Manual
7700PTX-MVP Unidirectional UMD Protocol Translator
The corresponding configuration for outgoing Ethernet Sub-Port 1 would be:
IP Address: 192168.18.50
TCP Port: 9800

4.8.3. Route Configuration

Each incoming port/sub-port has a table of routes that specify to which outgoing port/sub-port the
incoming data is destined.
4.8.3.1.
Example 1
Suppose we have:
An Up/Down timer connected to serial port 1
Its output is intended for a PPV with a single UMD with PID 1
A PPV configured to receive Image Video data over TCP port 9800
The Serial 1 route configuration would be:
Route Number
1
Note: The Up/Down timer protocol provides no addressing. Thus, it must be configured via the Display
ID field. For the Up/Down protocol, the Display ID field must match the PID (Protocol ID) associated
with the UMD. The Display ID field takes 1 of 3 formats:
An individual display
A group of displays
All displays
Display IDs must be configured when using the Up/Down timer protocol.
4.8.3.2.
Example 2
Suppose we have:
An up/down timer connected to serial port 1
Its output is intended for two UMDs (PIDs 1 and 2) of a PPV with three UMDs
A PPV configured to receive Image Video data over TCP port 9800
7700PTX-MVP - 18
Outgoing Port
Outgoing Sub-Port
Eth1
1
Revision 1.9
Display ID
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

7700ptx-mvp

Table of Contents