Advertisement

If in chars is reported as 0 and you have an incoming serial connection configured:
Verify that the cabling between the 7700PTX-MVP and OVE is correct
Verify that the serial settings are correct
Recall that any changes to serial settings require a reboot of the 7700PTX-MVP
If in chars is reported as 0 and you have an incoming Ethernet Sub-Port connection configured:
Verify that the IP address and TCP port incoming protocol translation settings are correct
Use a computer to ping both the 7700PTX-MVP and the host transmitting data to the 7700PTX-
MVP.
5.2.

CHECKING OUTGOING COMMUNICATION

5.2.1. Serial

Once the route for a given port has been configured to point to an outgoing serial port, one can check if
data is being transmitted over that serial port using the following method:
1. From the Main Menu select Engineering/Debug.
2. Select Show task statistics.
3. Under the heading outgoing serial port statistics... you'll see a table whose rows correspond to
each outgoing serial port (S1 – S4). Figure 5-2 provides an example.
4. The column Out Cmds lists, in hexadecimal, the number of commands the 7700PTX-MVP has
sent out to each serial port.
7700PTX-MVP Unidirectional UMD Protocol Translator
Revision 1.9
7700 MultiFrame Manual
7700PTX-MVP - 23