Troubleshooting Tips; Checking Incoming Communication; Figure 5-1: Incoming Communication - evertz 7700 Manual

Unidirectional umd protocol translator
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

7700 MultiFrame Manual
7700PTX-MVP Unidirectional UMD Protocol Translator
5.

TROUBLESHOOTING TIPS

5.1.

CHECKING INCOMING COMMUNICATION

Once the incoming protocol translation configuration has been set for a given port, one can check if
data is being received using the following method:
1. From the Main Menu select Engineering/Debug.
2. Select Show task statistics.
3. Under the heading framer statistics... you'll see a table whose rows correspond to each
configured incoming port. Figure 5-1 shows an Up/Down timer configured on serial port 2 and
an Image Video console on Ethernet Sub-Port 1.
4. The column labelled in chars reports the number, in hexadecimal, of protocol characters
received by the 7700PTX-MVP. As per Figure 5-1, serial port 2 has received 0x24 protocol
characters. Ethernet Sub-Port 1 has received no data since its in chars field is 0.
Generally speaking, in chars and valid cmds out should be non-zero. The remaining columns should
be reported as 0.
7700PTX-MVP - 22

Figure 5-1: Incoming Communication

Revision 1.9