Warning: ERR Sens4 & ERR
Sens5
ERR Sens4
Warnings ERR Sens4 or ERR Sens5 in-
dicate that the machine has failed
to properly detect upper water level
in the ultrasonic cleaning tank.
The Degritter has three pairs of
water level sensing pins near the
top of the ultrasonic cleaning tank.
These are visible when the rubber
gasket has been removed from
around the record insertion slot. The
issue can be caused by either ex-
cessive foaming that has left some
foam on the pins once the water
is pumped out, the pins that have
become dirty and need cleaning, or
by slight misalignment of the angle
of the pins.
For cleaning the pins, turn the
Degritter off from the AC switch
on the back of the machine and
detach the power cable. Remove
the rubber cover from around the
record insertion slot and locate the
water level sensing pins near the
top of the ultrasonic cleaning tank.
Clean the pins by gently rubbing
them with a toothbrush that has
been wet with 10% vinegar. Take
care not to bend the pins. Rinse the
toothbrush and remove the leftover
vinegar from the pins with a tooth-
brush wet in purified water. Follow
up with running 3 shortest washing
cycles with 1 Revolution program
and High water level setting without
a record to clean the ultrasonic
cleaning tank. Replace the water
before cleaning the records again.
For adjusting the alignment of the
water sensing pins, refer to the
Guide for troubleshooting: ERR
Sens4 & ERR Sens5 manual available
on our website degritter.com under
troubleshooting section.
Ultrasonic Error 1
Ultrasonic
Error 1
The warning indicates that the
connection between the machine's
control board and the ultrasonic gen-
erator has failed.
Please restart the unit manually from
the back panel, wait 10 seconds and
turn the machine on again. If the issue
persists, contact
support@degritter.com for help.