Degritter MARK II User Manual page 37

Automatic record cleaning machine
Table of Contents

Advertisement

Use two water tanks when
cleaning a larger number of
records. Swap water tanks
between cycles, so that one
tank can cool while the other
one is in use.
Place distilled water ice cubes
or a small ice pack in the re-
movable water tank while the
machine is in use.
Machine is foaming
excessively
It is normal to have small amounts
of foam on the record during the
washing cycle, but if the machine is
generating too much foam, then it
can cause water droplets running
down on the record label.
To prevent foaming:
Make sure that you are not ex-
ceeding the maximum amount
of cleaning fluid per water tank.
Degritter cleaning fluid should
be added only once per water
tank. Do not add additional
fluid when topping up the re-
movable water tank.
If there is a chance that too
much cleaning fluid has been
used or if you have experiment-
ed with other cleaning fluids,
then please clean the machine
as described in the 09 Cleaning
the machine.
Turn off the machine from the
switch on the back when re-
placing the water tank. Turning
the machine off and on from
the switch will start booting up
with priming. Properly primed
pumps will generate less foam.
Make sure that the filter has not
clogged. Clean the filter after
every 50 cycles.
Fill the removable water tank
with as much water as you feel
comfortable carrying.
Set the water level setting to
Medium. The surface skimming
filtration is pulling water into
the filter quite close to the
water line. In rare cases the Low
water level setting can cause
the filtration pump to suck in
air which will cause additional
foaming. Make sure that the
removable water tank is all the
way in. Press it gently after the
tank has been inserted.
37

Advertisement

Table of Contents
loading

Table of Contents