Troubleshooting guide
Record is not aligned
properly
Record does not get wet
Thick records get stuck
38
Record is not aligned
properly
When the record in the machine tilts
to one side and rubs against the
rubber gasket that is around the
record insertion slot, then most likely
there is a problem with the align-
ment of the plastic rollers located
at the top right side of the machine
that revolve the record.
To solve the issue, remove the
rubber gasket from around the
record insertion slot. Use a large
flat headed screwdriver to shift the
roller on the top right side of the
machine on its shaft slightly. The
shaft of this roller is connected to a
motor driving the belt drive and the
roller has been placed on the shaft
with a tight fit. It is possible to move
the roller's position slightly by press-
ing on its sides with a screwdriver.
Before inserting anything into the
Degritter make sure that the device
has been turned off from the AC
switch at the back and also detach
the power cable from the machine.
Record does not get wet
On some occasions, during the
washing cycle, the side of the
record exiting the ultrasonic clean-
ing tank can look almost dry. The
cleaning fluid acting as a sur-
factant together with the back and
forth movement of the record can
cause almost all the water to flow
off. When the water level inside the
ultrasonic cleaning tank is close to
the label during washing, then there
is no reason to be alarmed.