Warning: Add Water
Add Water warning is displayed
when there is no water or not
enough water in the removable
water tank to fill the ultrasonic
cleaning tank. Water can evaporate
during washing and drying cycles
and the water tank may need
topping up.
If there is enough water in the water
tank, then it can indicate that the
removable water tank has not been
inserted properly and the machine
is having trouble pumping sufficient
amounts of water from there.
When previous cases have been
checked, then the cause may be a
clogged pump or valve. To clean the
valves, start the Machine mainte-
nance cycle manually. The main-
tenance program will pump water
back and forth th rough the valves
and may remove debris stuck in
there.
To start Machine maintenance
navigate to the Degas program in
the menu. Press and hold the left
button and immediately press the
right button..
If this solves the issue, then clean
the machine with vinegar as de-
scribed in Cleaning the machine
section.
You can also try restarting the unit
manually from the back panel.
If the issue persists, contact
support@degritter.com for help.