NY Monitor Link Cables

The following table lists the recommended cables and connectors for the NY Monitor Link cable appli-
cations.
Maximum length
Manufacturer
Cable type
Category type
Cable sheath
Conductor pairs/size/type
Overall shielding
Pair shielding
Maximum outer diameter
Maximum bending radius of cable in a
fixed position
Maximum temperature for a cable in a
fixed position
RJ45 connectors
Additional Information
When making cables, connect the shield to the connectors at both ends.
NY Monitor Link Cable Clearance
The NY Monitor Link cable requires a minimum clearance from the connector entry to prevent exces-
sive strain on the connector and cable assembly.
The minimum clearance consists of the sum of:
• Connector length
• Maximum bending radius of cable in a fixed position
NY-series Industrial Panel PC Hardware User's Manual (W557)
Item
light industrial en-
25 m
Lapp
2170196
Cat 6A
Halogen free
4 x 2 x AWG23/1
Aluminum foil
Aluminum foil
7.6 mm
31 mm
60°C
Manufacturer
Stewart Connector
Partnumber
SS39200-027 or
SS39200-030
Connector length
30 mm
Intra cabinet or
Inter cabinet
vironment
100 m
Lapp
2170614
Cat 7
Halogen free
4 x 2 x AWG23/1
Copper braid
Aluminum foil
7.7 mm
31 mm
60°C
Stewart Connector
SS39200-027 or
SS39200-030
30 mm
3 Hardware Overview
Inter cabinet and
harsh industrial
environment
100 m
Lapp
2170466
Cat 6A
Halogen free
4 x 2 x AWG22/1
Copper braid
Aluminum foil
9.0 mm
90 mm
80°C
Lapp
21700600 (T568A)
or 21700601
(T568B)
50 mm