Control Commands Via Lan - Panasonic PT-REZ12 Operating Instructions Manual

Hide thumbs Also See for PT-REZ12:
Table of Contents

Advertisement

r RASTER PATTERN
Performance
No operation
OFF
WHITE
YELLOW
CYAN
GREEN
MAGENTA
RED
BLUE
BLACK
USER LOGO
No operation
r ENABLE/DISABLE
Operation for all channels is not accepted when set to "Disable".
Performance
Disable
Enable
Note
f If the projector is operated using the remote control or the control panel, or by the control command while controlling the projector using the
Art-Net function, the setting of the DMX controller or computer application may be different from the projector status. To reflect the controls
of all channels to the projector, set "ENABLE/DISABLE" of channel 11 to "Disable" and then back to "Enable".
f To create and register the [USER LOGO] image, use "Logo Transfer Software". The software can be downloaded from the following website.
https://panasonic.net/cns/projector/

Control commands via LAN

The projector can be controlled via the <LAN> terminal equipped on the projector as standard or the <DIGITAL
LINK IN/LAN> terminal of the optional DIGITAL LINK Terminal Board (Model No.: TY-SB01DL) installed in the slot
by using the control command format via the <SERIAL IN> terminal.
For examples of the available commands, refer to "Control command" (x page 287).
Note
f To send/receive the command via LAN, it is necessary to set the password of the administrator account. (x page 209)
When connecting in protect mode
Connecting
Following is the connection method when the [NETWORK] menu → [NETWORK SECURITY] → [COMMAND
PROTECT] is set to [ENABLE].
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Port number
2)
Check the response from the projector.
280 - ENGLISH
Chapter 7 Appendix — Technical information
Obtain from the [NETWORK] menu → [NETWORK STATUS].
Obtain from the [NETWORK] menu → [NETWORK CONTROL] → [COMMAND PORT].
Parameter
0-15
16-31
32-47
48-63
64-79
80-95
96-111
112-127
128-143
144-159
160-175
176-255
Parameter
0-127
128-255
Default value
0
Default value
0

Advertisement