4
Display the names and IP addresses of projectors in same group detected over the network.
For IPv6 address, "(IPv6)" is displayed instead of the IP address.
5
Display the status by color.
Green: There is an allowance for brightness correction.
Yellow: There is little allowance for brightness correction.
Red: There is a brightness control error.
6
Display error detailed messages.
7
Display error messages.
When the message [Failed to apply BRIGHTNESS CONTROL to some projectors.] appears, it means that synchronization with the
projector displayed in red has failed.
Press as to select the projector displayed in red, and press the <ENTER> button to display the error details.
8
Update to the latest status information.
r Error details
Error message
[Exceed maximum number of
projectors.]
[Please check the COMMAND
CONTROL setting.]
[Please check the USER NAME
and PASSWORD in the COMMAND
CONTROL setting.]
[Cannot apply BRIGHTNESS
CONTROL. Please check projector
status.]
[Brightness Sensor Error]
*1 "Multi Monitoring & Control Software" can be downloaded from the following website.
https://panasonic.net/cns/projector/
Note
f If the synchronized projectors are not displayed in the list, check the following:
g Are there devices with the same IP address on the network?
g Are the LAN cables connected correctly? (x page 216)
g Are the subnets of the projectors the same?
g Are the same [LINK] settings applied to a group?
f Refer to [PROJECTOR NAME] (x page 206) or "[Network config] page" (x page 234) on how to change the projector name.
Setting [STARTUP CALIBRATION]
Set whether to measure the brightness and color of the light source when the power is turned on.
1)
Press as to select [BRIGHTNESS CONTROL].
2)
Press the <ENTER> button.
f The [BRIGHTNESS CONTROL] screen is displayed.
3)
Press as to select [STARTUP CALIBRATION].
4)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
Note
f The [STARTUP CALIBRATION] setting will be reflected at the time when the item is switched using qw.
f The [STARTUP CALIBRATION] setting item is common with the following menu item.
g The [PROJECTOR SETUP] menu → [BRIGHTNESS CONTROL] → [BRIGHTNESS CONTROL SETUP] → [STARTUP CALIBRATION]
166 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
f Limit the number of projectors in one group to eight.
f To synchronize nine or more projectors, use a computer and "Multi Monitoring & Control
Software"
.
*1
f Set the password of the administrator account.
f Set [NETWORK CONTROL] → [COMMAND CONTROL] to [ON] for the projector in error.
f Set [NETWORK CONTROL] → [COMMAND PORT] of all linked projectors to the same value.
f Set the administrator account (user name and password) of all linked projectors to the same
setting.
f The projector is in standby. Switch on the power.
f There is a problem with the brightness sensor. If problems persist even after switching on the
power, consult your dealer.
Does not measure the brightness and color of the light source when the power is turned on.
Measures the brightness and color of the light source by the brightness sensor after the power is
turned on and the light source is illuminated.
Measures to take