TOHATSU EverRun MX 15E2 Owner's Manual page 47

Table of Contents

Advertisement

ENOM00085-A
Flushing by test tank
ENOW00036-1A
CAUTION
When starting the outboard motor in the
test tank, make sure that:
1. Water level is at least 10 cm (4 in.) above
the anti-ventilation plate to avoid over-
heating of the engine.
2. Run at idling only
3. Remove the propeller
(See page 53)
3
2
1. Test tank
2. Water
3. Over 10 cm (4 in.)
ENOM01903-0
Gear case flushing device
ENOW00082-0
WARNING
Never start or operate the engine indoors or
in any space which is not well ventilated.
Exhaust gas contains carbon monoxide, a
colorless and odorless gas which can be fatal
if inhaled for any length of time.
ENOW00986-0
CAUTION
Never leave the outboard motor unattended
while running on the flushing devise. When
the flushing devise slip off from the gear
case, the engine will overheat and may cause
serious damage.
1. Fully tilt down the outboard motor.
2. With the propeller removed, seal the
sub-water inlet with a tape to prevent
air from being sucked into the water
pump.
1
1. Sub-water inlet
2. Tape
3. Install the gear case flushing device on
gear case so that the rubber cups
ENOF00863-0
cover the cooling water inlets tightly.
4. Connect a water hose to the flushing
devise and turn on the water and
adjust the flow so that excess water
continues leaking out from around
the rubber cups to ensure the engine
is receiving an adequate supply of
cooling water.
1. Gear case flushing device
INSPECTION AND MAINTENANCE
1
2
1
47
ENOF02559-0
10
ENOF01420-C

Advertisement

Table of Contents
loading