Operation

Weight Check

Perform the weight check Procedure at startup and
after rebuild.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection and
splashing, keep fingers and other body parts away
from the spray tip.
To avoid injury from toxic fluids or fumes, such as
splashing in the eyes or on skin, wear appropriate
personal protective equipment.
1. Prepare several cups.
2. Weigh one cup and record the weight.
3. Dispense into a waste container to prime the PSM
machine.
4. Place the cup under Dispense Valve (AB, page 8)
and cycle the machine one time.
5. Repeat by using a cup each time.
6. Re-weigh all cups and record weights.
7. Subtract weight of empty cups from weight of filled
cups to get material weights.
8. Check if the material weights stay within normal
range. The normal range changes per operators
needs.
40

Shutdown

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow Pressure Relief
Procedure.
To avoid injury from toxic fluids or fumes, such as
splashing in the eyes or on skin, wear appropriate
personal protective equipment.
1. Place a waste container below the Dispense Valve
(AB, page 8).
2. Perform the Pressure Relief Procedure on page
41.
3. Turn off the system power.
4. Wipe the dispense outlet with a clean rag. Be
careful to avoid contact between dispense materials.
5. If necessary, isolate the output needle from the air
by using sealing medium, such as alcohol,
kerosene or oil paper. Chose proper sealing
medium according to different types of materials.
3A7273B