Graco PSM Instructions Manual page 35

1k precision metering system
Table of Contents

Advertisement

Advanced Setup Screen - 2
F
. 28 Advanced Setup Screen - 2
IG
On the Advanced Setup Screen 2, select the
to display the Advanced Setup Screen 3. Select the
button to display the System Main Screen. Select
the
button to return to the previous screen. Select
the
button to continue to the next screen.
The content and functions of this screen are as follows:
Mode selected by
Options for mode selection input include Display,
Distributed IO or Gateway.
If 'Distributed IO' or 'Gateway' is selected, in
Automatic mode, the shot or bead working mode
(Sequence mode will be inaccessible) must be
controlled by customer signals. The operator will
not be able to change working mode using the
touch screen.
If 'Display' is selected, working mode will include
Shot, Bead and Sequence mode. The operator will
be able to change working mode using the touch
screen.
Shot No. selected by
The operator may choose whether the style number
may be changed by Display, Distributed IO or Gateway.
Job start resource, Dispense resource, Purge
resource, Reload resource and Precharge control
The operator may choose whether these resources
come from Distributed I/O communication or Gateway
(Profinet) communication. Display option is unavailable.
3A7273B
Advanced Setup Screen - 3
F
. 29 Advanced Setup Screen - 3
IG
button
On the Advanced Setup Screen 3, select the
to display the Advanced Setup Screen 2. Select the
button to display the System Main Screen. Select
the
button to return to the previous screen. Select
the
button to continue to the next screen.
The content and functions of this screen are as follows:
Sequence mode
Press the button to enable or disable this function. The
green color of the button indicates the sequence mode
is enabled.
If this function is enabled, the PSM system will run in
sequence mode. In this mode, the operator can edit the
working sequence (The sequence includes 16 steps
maximum. The operator can edit step 1 to 14, as step 0
and 15 are tied to pre-charge and de-pressurization).
When the system works in automatic status, the
Customer Control Box (J) can send 'dispense' signal to
start the sequence mode and then dispense step by
step.
Pressure check in homing
HMI Display Operation and Identification