HMI Display Operation and Identification
Press the button to enable or disable this function. The
green color of the button indicates pressure check after
homing is enabled.
If this function is selected, the system pressure will be
checked when the piston is at the home position.
Pressure sensor offset
The operator may input values to adjust the pressure
offset on the sensors.
Pressure limit
If the pressure is higher than the preset max pressure,
the system will activate the alarm and send the alarm
signal to customer system.
36

Advanced Screen

F
. 30 Advanced Screen
IG
On the Advanced Screen, select the
display the System Main Screen. Advanced screen is
dedicated to repairing and testing the system. After
navigating to this screen, the logic relationship between
the drive motor, reloading valves and dispense valves
will be overrode and the operator may control each part
individually. For this reason, only qualified personnel
who have received equipment maintenance training
should be authorized to navigate to this screen and
perform system check.
The content and functions of this screen are as follows:
Dispense rate
Click at the column to set the speed of the slide block.
Piston move up
This button is for motor, push block and piston tests.
Jog control pistons and slide block move away from the
outlet port.
button to