When the boiling process is finished,
5 beeps will sound, the thermopot will
switch to the maintain temperature mode,
the indicator light (16) will go out and the
maintain temperature mode indicator light
(17) will come on.
If the water temperature drops significantly
below the set temperature, e.g. you have
added cold water, the boiling mode will be
activated again. After water is boiled, its tem-
perature will be maintained according to the
set temperature value on the indicator (15).
You can also start the re-boiling process by
pressing the button (20) «REPEAT».
To disconnect the thermopot from the mains,
disconnect the power plug (14) from the
mains socket.
Open the thermopot lid (6) and wait until it
cools down completely, remove the lid (6)
(see the chapter Before the first use), drain
the water, install the lid (6) back to its place
and put the thermopot away for storage.
Attention! Be careful when pouring out water to
avoid burns by hot water.
Power-saving function «ЕСО»
Power-saving with light sensor (19): in unlocked
state after pressing the «ECO» button (24)
(pic. 8), the «ECO» indicator (25) in the right
display area will light up. When the light sensor
detects that it is night time (dark) or the ambi-
ent light is weak, the «power saving» indicator will
blink and the thermopot will automatically enter
the 40 °C temperature saving mode to achieve
the energy saving effect. Once the ambient light
is sufficient, the power saving mode will be auto-
matically deactivated and the thermopot will re-
turn to the set temperature mode to restore the
set water temperature.
Automatic switch-off function
If you do not use the thermopot for 48 hours (no
button on the control panel has been pressed),
the thermopot automatically switches off and en-
ters standby mode.
Overheat protection
If you accidentally turn on the thermopot without
water, the automatic overheating protection will
activate and the display will show the error code
«Е3» and the control panel will lock.
In this case, unplug the power cord plug from the
wall outlet, then fill the thermopot with water and
plug the power cord plug into the wall outlet, the
thermopot will operate normally.
Error codes on the display
and their meaning
The thermopot may display errors when it is used
incorrectly, when it breaks down, or as a result of
a system malfunction. The table below gives error
codes, their brief decoding and recommendations
for solution.
Error
Possible cause
code
E1
Open circuit in the
overheat protection
circuit
E2
Short circuit in the
overheating pro-
tection circuit
E3
The overheating
protection system
has been tripped

CLEANING AND CARE

Before cleaning, disconnect the thermopot
from the mains, pour out water and let the
thermopot cool down completely.
Open the lid (8) and carefully tilting the ther-
mopot drain the remaining water, then close
the lid (8).
Clean the outer surface of the thermopot with
a slightly damp cloth and then wipe it dry.
Use neutral detergents to remove dirt; do not
use metal brushes, abrasive detergents and
solvents.
Do not immerse the thermopot and the power
cord into water and other liquids.
Do not wash the thermopot in a dishwashing
machine.
Stains on the inner surface of the thermopot
The inner surface of the metal flask may change
its color under the influence of different water
impurities.
You can remove the stains with citric acid or
vinegar.
To remove the flavour of citric acid or vinegar,
boil water and pour it out.
Repeat this procedure until the smell and taste
vanish completely.
12
Action required
Contact an autho-
rized service center
for diagnostics and
repair
Contact an autho-
rized service center
for diagnostics and
repair
See section «Over-
heating protection»