Recording Status; Recording Statistics; Image Posting - Bosch DINION 5100i IR User Manual

Table of Contents

Advertisement

40
en | Configuration

Recording status

The graphic indicates the recording activity. An animated graphic is displayed when recording
is taking place.
Activating recording
After completing configuration, activate the recording schedule and start scheduled recording.
Once activated, the Recording Profiles and the Recording Scheduler are deactivated and the
configuration cannot be modified. Stop scheduled recording to modify the configuration.
1.
2.
Click Set to apply the changes.
4.5.5
Recording Status
Details of the recording status are displayed here for information. These settings cannot be
changed.
4.5.6

Recording Statistics

The bit rate of the recorded video (blue) and other data (grey), such as audio and metadata,
are shown in the graphic.
Recording
Identifies the current recording profile (1 or 2).
Zoom
Identifies the current zoom factor of the camera (1x, 2x, 4x, or 8x).
Averaging period
Select the appropriate averaging period as a means of stabilizing the long term bit rate.
4.5.7

Image Posting

Save individual JPEG images on an FTP server at specific intervals.
JPEG
Image size
Select the size of the JPEG images that are to be sent from the camera. JPEG resolution
corresponds to the highest setting from the two data streams.
File name
Select how file names are created for the individual images that are transmitted.
VCA overlays
If you have enabled the display of VCA overlays on the Appearance page, select the VCA
overlays check box to have the overlays also visible in the JPEG image.
Posting interval
Enter the interval in seconds at which the images are sent to an FTP server. Enter zero for no
images to be sent.
2023-08 | V01 | F.01U.393.997
Click Start to activate the recording schedule.
Click Stop to deactivate the recording schedule. Recordings that are currently running are
interrupted and the configuration can be modified.
Overwrite: The same file name is always used and any existing file will be overwritten by
the current file.
Increment: A number from 000 to 255 is added to the file name and automatically
incremented by 1. When it reaches 255, it starts again from 000.
Date/time suffix: The date and time are automatically added to the file name. When
setting this parameter, make sure that the date and time of the device are always set
correctly. For example, the file snap011005_114530.jpg was stored on October 1, 2005 at
11:45 and 30 seconds.