Mounting the camera Day/Night switching Configuration Menus 4.1.1 Top level menus 4.1.2 Menu navigation Camera control communication (Bilinx) Main menu structure 4.3.1 Shutter/AGC submenu 4.3.2 Day/Night submenu 4.3.3 Color submenu Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 4
| Table of Contents Dinion Day/Night Camera 4.3.4 VMD submenu (remotely via Bilinx only) Install menu structure 4.4.1 Lens Wizard submenu 4.4.2 Alarm submenu 4.4.3 Defaults submenu Technical Data Specifications Glossary F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
If not avoided, this could result in property damage or risk of damage to the unit. NOTICE! This symbol indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
10. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
Dinion Day/Night Camera Safety | en Important notices Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
Federal Communications Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Page 9
(FCC), peut s'avérer utile : How to Identify and Resolve Radio-TV Interference Problems (Comment identifier et résoudre les problèmes d’interférences de radio et de télévision). Cette brochure est disponible auprès du U.S. Government Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Dinion Day/Night Camera Safety | en Bosch notices Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes. CAUTION! The camera module is a sensitive device and must be handled carefully. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 5 mm (0.2 in) of insulation. – Push in the tabs and insert the wires. Note These connections are not polarity sensitive. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
A L A R M Figure 3.3 BNC connectors 3.2.1 Output Video signal The camera has a BNC connector to connect the video coax cable with a male BNC connector. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
22 kOhm pull-up to +3.3 V. – Alarm in: configurable as active low or active high. – Max. 42 V allowed between camera ground and each of the relay pins. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
(OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Press and hold the center key for more than 1 second until the Install menu appears. Select Wizard and move cursor to the Set Back Focus Now item. Turn the back focus adjustment as required. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 18
Press and hold the center key for more than 1 second until all the menus disappear. Close the side door panel. Note: To backfucus a zoom lens, see the zoom lens installation guide. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
There are three different methods of controlling the IR filter: – via an alarm input, – via Bilinx communication, or – automatically, based on the observed light levels. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
4.1.2 Menu navigation Five keys, located behind the side door panel, are used for navigating through menu system. Figure 4.1 Side panel door Figure 4.2 Menu/select key F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Bilinx communications can only be disabled using the buttons on the camera. Disabled camera buttons When the Bilinx communications link is active, the buttons on the camera are disabled. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Line lock - to lock to the AC power supply Vphase 0, 2 . . . 358 Adjusts the vertical phase (only available if sync = line lock). Exit Exit the menu F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
On, Off Autoblack On automatically increases the visibility of details even when scene contrast is less than full-range due to mist, fog, etc. EXIT Returns to main menu. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
A high (positive) value means that the camera switches to monochrome at a higher light level. EXIT Returns to main menu. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Select to enter the area set-up menu to define the detection area. Motion Indicates the peak of measured motion indicator in the selected area. Press either the right, left or center navigation button to reset. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 26
Because of this, it is recommended to not connect the VMD- triggered alarm output of the camera to a monitored alarm system, as the false-positive alarms may be considered a nuisance. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Select to fully open the iris. Follow the instructions below for setting the backfocus for your particular lens type. After focusing the object of interest remains in focus under bright and low light conditions. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 28
Point the camera at the scene it will be mostly viewing. Adjust the level potentiometer located on the lens until the Level bar is in the central position. Exit the menu. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Page 29
(2 to 3 seconds) Alarm out - Normally Select how the output relay activates. Relay open, Normally closed EXIT Returns to Install menu. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Restores all settings to their default (factory) values. Select YES, then press the Menu/Select button to restore all values. When completed the message RESTORED! is shown. EXIT Returns to Install menu. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Dinion Day/Night Camera Technical Data | en Technical Data Specifications Type number LTC0465/11 LTC0465/21 LTC0465/51 LTC0465/61 Standard NTSC NTSC Active pixels 752 x 582 768 x 494 752 x 582 768 x 494 Rated supply +12 VDC +12 VDC 230 VAC...
Page 32
Tripod mount Two 1/4" 20 UNC - isolated (bottom) and non-isolated (top) Operating -20 °C to +55 °C (-4 °F to +131 °F) temperature Controls OSD with softkey operation F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Page 33
The electronics that regulate the gain or amplification of the video signal. AGC is used in low-light conditions with the iris fully open. Back Light Compensation (BLC) Selectively amplifies parts of the image to compensate for large Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 34
(night conditions). This is achieved by removing the infrared cut filter required for good color rendition. The sensitivity can be F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Page 35
The measure of the visible area within the camera’s field of view. The larger the focal length, the smaller the field of view. The smaller the focal length, the wider the field of view. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 36
The international (SI) unit of measurement of the intensity of light. It is equal to the illumination of a surface one meter away from a single candle. On-screen Display: Menus are shown on the display monitor. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...
Page 37
Signal-to-noise ratio The ratio between a useful video signal and unwanted noise measured in dB. Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01...
Page 38
A scene with both very low and very high illumination levels requires a camera with a wide dynamic range to handle it correctly and produce a useful image. F.01U.163.823 | v1.0 | 2010.01 Installation and Operation manual Bosch Security Systems...