Page 1
Dinion – LTC 0610 & LTC 0485 series cameras Installation Instructions Installatiehandleiding 15-bit digital color camera 15-bits digitale kleurencamera Manuel d’installation Manuale di installazione Caméra numérique couleur Telecamera digitale a colori 15 bits 15 bit Installationshandbuch Manual de Instalação 15-Bit digitale Farbkamera Câmara digital policromática de 15 bits Manual de instalación...
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat. Bosch Security Systems | 2003-10 | V0.5...
Page 4
To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus. Bosch Security Systems | 2003-10 | V0.5...
Bosch authorization, could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com Bosch Security Systems | 2003-10 | V0.5...
NTSC NTSC Supply voltage 24 VAC or 12 VDC 230 VAC 50Hz 110 VAC 60Hz CCD type 1/3" Caution Ensure that your power supply matches the rated voltage of your camera before installing. Bosch Security Systems | 2003-10 | V0.5...
Page 7
CCD protection cap • Spare lens connector (male) • These instructions Note If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier. Bosch Security Systems | 2003-10 | V0.5...
(these connections are not polarity sensitive). • use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 10mm (0.4") of insulation. Composite video Bosch Security Systems | 2003-10 | V0.5...
Page 9
Dinion | Installation Manual EN | 9 Sync Y/C socket GND Y GND C Bosch Security Systems | 2003-10 | V0.5...
To avoid damaging the CCD sensor when using a C-mount lens, turn the red back focus ring counterclockwise until it stops (see back focus adjustment) before mounting the lens. Lenses weighing more than 0.5 kg (1. 1 lbs) must be separately supported. Bosch Security Systems | 2003-10 | V0.5...
Page 11
If a short circuit is detected on the lens connector, the on-screen display (OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections. Bosch Security Systems | 2003-10 | V0.5...
To adjust back focus: Open the slide door at the side of the camera Unlock the back focus locking button. Turn the back focus adjustment as required. Lock the back focus locking button. Bosch Security Systems | 2003-10 | V0.5...
The camera can be mounted from the top or bottom. The bottom mounting is isolated from ground. With outdoor scenes, a DC-iris lens is recommended. Caution Do not point the camera/lens into direct sunlight. Bosch Security Systems | 2003-10 | V0.5...
You can also set up Bilinx™ so that the camera buttons remain disabled even when Bilinx™ is not actively controlling the camera. This prevents unauthorized change of the camera settings. Bosch Security Systems | 2003-10 | V0.5...
BLACK LEVEL CONTOUR XF-DYNAMIC MODE X COLOR WHITE BALANCE WBSPEED R GAIN G-GAIN B-GAIN SATURATION MODE X BLC BLC LEVEL BLC AREA MODE X VMD AREA ACTIVE MOTION SENSITIVITY MODE X DEFAULTS CONFIRM Bosch Security Systems | 2003-10 | V0.5...
Page 16
ACTIVE COMMUNICATION ACTION CABLE COMP COMP LEVEL ALARM OUT ALARM INSTALL SYNC SYNC DETECTED SYNC V PHASE H PHASE SUB PHASE INSTALL CAMERA ID CAMERA ID ID POSITION MAC ADDRESS ALL DEFAULTS CONFIRM Bosch Security Systems | 2003-10 | V0.5...
Page 17
When in a menu, quickly pressing the menu/select key twice restores the selected item to its factory default. • To close all menus at once from any menu, select the Exit item and hold down the menu/select key until the menu display disappears. Bosch Security Systems | 2003-10 | V0.5...
-15 - 0 - +15 Adjust the balance between peak and average AVERAGE video control ALC SPEED Slow, Medium, Fast Adjust the speed of the video level control loop. EXIT Return to MODE menu Bosch Security Systems | 2003-10 | V0.5...
Page 19
• In AUTO mode, the camera automatically inches to monochrome in low-light conditions. • In FORCED mode, the camera remains in high- sensitivity monochrome operation. EXIT Return to the ALC menu Bosch Security Systems | 2003-10 | V0.5...
WB SPEED Slow, Medium, Fast Adjust the speed of the white balance control loop. RED gain -5 - 0 - +5 • ATW mode and AWB hold mode: adjusts the Red gain to optimize the white point. Bosch Security Systems | 2003-10 | V0.5...
Page 21
Video Motion Detection (VMD) submenu Function Selection Description OFF, SIL, OSD When VMD is enabled and the camera can generate SIL (silent) or OSD (monitor alarm generates on-screen message) motion alarms. Bosch Security Systems | 2003-10 | V0.5...
Selection Description MODE Select to restore the factory defaults. A DEFAULTS confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset. EXIT Return to MODE menu Bosch Security Systems | 2003-10 | V0.5...
Unlock the back focus locking button. Access the Lens Wizard menu. SET BACK FOCUS NOW is highlighted in the menu. Turn the back focus adjustment as required. Lock the back focus locking button. Exit the menu. Bosch Security Systems | 2003-10 | V0.5...
Page 24
1000m (3000ft). For optimum results select the coaxial cable type used or if unknown, DEFAULT. COMP 0, 1, .. +15 Sets the level of cable compensation. LEVEL ALARM Select submenu EXIT Return to the INSTALL menu Bosch Security Systems | 2003-10 | V0.5...
Page 25
Adjusts the sub-carrier phase offset (when in EXT PHASE LOCK mode and a valid sub-carrier is detected). EXIT Return to the INSTALL menu Note VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal. Bosch Security Systems | 2003-10 | V0.5...
Page 26
To avoid loss of communication on an installed camera, the COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons. Bosch Security Systems | 2003-10 | V0.5...
Video output 1 Vpp, 75 Ohm Y/C output Y: 1 Vpp C: 0.3 Vpp Synchronization Internal or HV-lock or Genlock or Line Lock selectable Shutter AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable Bosch Security Systems | 2003-10 | V0.5...
Page 28
58 x 66 x 122 mm (HxWxL) without lens Weight 450g without lens Tripod Mount Bottom (isolated) and Top ¼" 20 UNC Operating -20° to 50° C temperature Controls OSD with softkey operation Bosch Security Systems | 2003-10 | V0.5...