COMMANDS
ASCII
ESC W
Hex
1Bh + 57h + n
Description
Sets the number of columns
This command selects the number of print columns. It must be changed at the beginning
of a line since it is not possible to print a line in two different modes, and it also causes
the line buffer to be cancelled. The number of columns is determined by <n>:
n = 035 columns
n = 142 columns
ASCII
ESC t
Hex
1Bh + 74h + n
Description
Selects the default font
Selects the new font to be used which automatically becomes the default font. This
means that following the next initialization, the font used will be the one that has just
been selected. The font number must be chosen from among the available ones, and
any request for n1 greater than the fonts available will be ignored. The font number is
displayed during set-up.
ASCII
ESC C
Hex
1Bh + 43h + n
Description
Selects print direction
This command selects print direction, i.e., in which direction the line is printed.
n1 == 0
n1 <> 0
ASCII
ESC l
Hex
1Bh + 6C + n
Description
Setting cutter status
This command selects cutter status, activating or disactivating it depending on the
status of <n>. If disactivated, <Esc i> and <ESC m> are ignored.
If the cutter is activated but for some reason is inactive (breakdown, connector unplugged,
etc.) the flag is reset. Cutter presence is tested during power-up and if it is not present,
it is disactivated automatically.
n1 == 0
n1 <> 0
normal printing
reverse printing
cutter disactivated
cutter activated