11.
Overhead Installation: Install overhead
assembly to Mounting Bracket with (2) M10-
1.5 x 20mm HHCS, and (2) M10-1.5 Flanged
Locknut Fig. 11. Tighten bolts at center of
overhead assembly.
12.
Power Unit: First install a star washer onto
all of the (4) 5/16"-18NC x 1" HHCS. This
is very important for grounding. Put the (4)
5/16"-18NC x 1" HHCS thru holes in power
unit bracket, Fig.12.
up to column bracket and install (4) 5/16" star
washers and 5/16" Nuts. Install and hand
tighten fitting to pump until O-ring is seated.
Continue to tighten the locknut until the nut and
washer bottom out against the pump manifold.
NOTE:
You may still be able to rotate the fitting.
This is acceptable unless there is seepage at
the O-ring. If so, slightly tighten the locknut.
Use (4)5/16"-18NC
x1" lg. HHCS
and Nuts
Fig. 12
On all four bolts, place
On all four bolts, place(2)
(2) 5/16" Star Washers
5/16" Star Washers
Fill Breather Cap
Mount unit with motor
Fig. 12
Use (4)5/16"-18NC
x1" lg. HHCS
and Nuts
Fill Breather Cap
0496-M005-0
Use M10-1.5 x 20mm
HHCS and Locknuts
Fig. 11