2. Power Unit Tee Cover Plate: While power unit
column is laying on the ground, install the cover plate
using (2) M4x6 Lg. PHMS Fig. 3.
3.
Hoses: Clean adapters and hose. Inspect all
threads for damage and hose ends to be sure they
are crimped.
Flared Fittings Tightening Procedure
1.
Screw the fittings together finger tight. Then,
using the proper size wrench, rotate the fitting
2-1/2 hex flats.
IMPORTANT:
Flare seat MUST NOT rotate
when tightening. Only the nut should turn.
2.
Back the fitting off one full turn.
3.
Again tighten the fittings finger tight; then using
a wrench, rotate the fitting 2-1/2 hex flats. This
will complete the tightening procedure and
develop a pressure tight seal.
CAUTION:
Overtightening will damage fitting
resulting in fluid leakage.
CAUTION:
Over tightening locknut may tear
O-ring or distort threads in pump manifold
outlet.
32
4.
on the ground push the lift carriage as high as
possible to install the power unit tee. Once carriage
is rasied, install the power unit tee and hoses to the
column Fig. 4.
CAUTION
Fig. 3
Fig. 4
Fig. 3

Power Unit Tee

Power Unit Tee
Carriage
Carriage
0496-M005-0
Fig. 2
Fig. 2
Fig. 3
Power Unit Tee: With the column still laying
: Overtightening will damage fitting
resulting in fluid leakage.
Hydraulic Hose
Hydraulic Hose
M4x6 Lg. PHMS
M4x6 Lg. PHMS