Extension Card For Analogue Clocks - WEMPE 20097/W Operating Instructions Manual

Digital main clock
Table of Contents

Advertisement

WEMPE digital main clock 20097
Operation

6.4.3 Extension card for analogue clocks

If an extension card for analogue clocks is installed in the unit, set the secondary clock line
as follows:
Two analogue lines are available:
LT: local time secondary clocks
SE: seconds secondary clocks
UT: UTC secondary clocks
f:
forwards running
fb: forwards and backwards running
M: minutes (or seconds) impulses
H: ½ minute (½ second) impulses
G: GORGITIME / 24-hour display
Setting of the analogue line:
1. Remove write protection ( 6.2.1).
2. Press the key 1 several times until
the following message appears on
the display:
3. Press the ENTER key for confirmation. The line number starts flashing.
(The analogue line that needs to be modified, can only be selected once again with the
key 2 if it has not been correctly selected in the main menu).
4. To make the desired settings of the analogue line:
– press the key 3 to set an UT, LT or seconds line,
– press the key 4 to merge two lines to one forwards and backwards running line,
– press the key 5 to set whether the output impulses are to be transmitted every
minute (second) "M" or every half-minute (second) "H".
Example for a forwards running
secondary clock line (local time) with
minutes impulse:
5. Press the ENTER key to confirm the modification.
To cancel the modifications, press the MENUE key twice.
6. Press the MENUE key to return to the time display.
30
V3.2a 05/2015

Advertisement

Table of Contents
loading

This manual is also suitable for:

20097Pro 20097/w

Table of Contents