WEMPE digital main clock 20097
Annex
9.6.8 Protocol MITEL
Data scope:
1 Start bit
7 Data bit
1 Parity bit (even)
2 Stop bit
4.800 Baud
transmission only if time is set up anew
Byte Mark
1 ESC
2 1
3 M
4 A
5 I
6 N
7 T
8 1
9 CR
10 S
11 X
12 2
13 0
14 0
15 0
16 CR
17 ESC
18 6
19 T
20 I
21 M
22 E
23 SPACE
24 10h
25 1h
26 :
27 10m
28 1m
29 CR
30 D
31 E
32 S
33 K
34 CR
35 ESC
36 1
64
Description
HEX1B
HEX0D
Carriage return
HEX0D
Carriage return
HEX1B
HEX20
Hour ten LT
Hour one LT
HEX3A
Minute ten LT
Minute one LT
HEX0D
Carriage return
HEX44
HEX45
HEX53
HEX4B
HEX0D
Carriage return
HEX1B
HEX1B
V3.2a 05/2015