Extension Card For Analogue Clocks - WEMPE 20097 Operating Instructions Manual

Digital main clock
Hide thumbs Also See for 20097:
Table of Contents

Advertisement

1.1.3 Extension card for analogue clocks

If an extension card for analogue clocks is installed in the unit, set the secondary clock line
as follows:
Two analogue lines are available:
LT: local time secondary clocks
SE: seconds secondary clocks
UT: UTC secondary clocks
f:
forwards running
fb: forwards and backwards running
M: minutes (or seconds) impulses
H: ½ minute (½ second) impulses
G: GORGITIME / 24-hour display
Setting of the analogue line:
1. Remove write protection (
2. Press the key 1 several times until
the following message appears on
the display:
3. Press the ENTER key for confirmation. The line number starts flashing.
(The analogue line that needs to be modified, can only be selected once again with the
key 2 if it has not been correctly selected in the main menu).
4. To make the desired settings of the analogue line:
– press the key 3 to set an UT, LT or seconds line,
– press the key 4 to merge two lines to one forwards and backwards running line,
– press the key 5 to set whether the output impulses are to be transmitted every
minute (second) "M" or every half-minute (second) "H".
Example for a forwards running
secondary clock line (local time) with
minutes impulse:
5. Press the ENTER key to confirm the modification.
To cancel the modifications, press the MENUE key twice.
6. Press the MENUE key to return to the time display.
V3.0 01/2011
WEMPE digital main clock 20097
1.1.1).
Operation
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents