9.6 Interface protocols

9.6.1 Standard protocol main clock 20097 (terminal 13 / 37)

Data scope:
1 Start bit
8 Data bit
Parity bit (none)
2 Stop bit
4.800 Baud
transmission once a second
Byte Mark
1 STX
2 U
3 10h
4 1h
5 10m
6 1m
7 10s
8 1s
9 D
10 10d
11 1d
12 10m
13 1m
14 1000y
15 100y
16 10y
17 1y
18 L
19 10h
20 1h
21 10m
22 1m
23 10s
24 1s
25 D
26 10d
27 1d
28 10m
29 1m
30 1000y
31 100y
32 10y
33 1y
34 LF
35 CR
36 ETX
V3.2 12/2014
Description
HEX02
Start of text
HEX55
Data transmission of the UTC-time
Hour ten
Hour one
Minute ten
Minute one
Second ten
Second one
HEX44
Data transmission of the UTC-date
Day ten
Day one
Month ten
Month one
Year thousand
Year hundred
Year ten
Year one
HEX4C
Data transmission of the LT-time
Hour ten
Hour one
Minute ten
Minute one
Second ten
Second one
HEX44
Data transmission of the LT-date
Day ten
Day one
Month ten
Month one
Year thousand
Year hundred
Year ten
Year one
HEX0A
Line feed
HEX0D
Carriage return
HEX03
End of text